Найти Датчик Давления , Дифференциальный Датчик Давления , Датчик Давления на Промышленность Directory, надежный производитель / поставщик / завод из Китая
Новые продукты
Вид оплаты: | L/C, T/T, D/P, Western Union, Paypal, Money Gram |
---|---|
Количество минимального заказа: | 1 |
Срок поставки: | 1 дней |
Модель: SMP858-DST
Pressure types | Differential pressure |
Measuring range | 10kPa-1MPa, |
Output signal | 4-20mA two wire, power supply: 10.5- 55VDC |
4-20mA+HART two wire, power supply: 16.5-55VDC | |
Reference accuracy | ±0.1% URL, optional ±0.075% URL |
Field of application | Pressure, level, differential pressure, density, interface,flow |
Diaphragm material | SS316L,Hastelloy C |
Stability | ±0.2% URL/5years |
Working temperature | -40-85ºC, LCD display unit:-20-70ºC |
Storage temperature | -40-110ºC, LCD display unit:-40-85ºC |
Media temperature | With silicone oil -40-120ºC |
With neobee oil -10-80ºC | |
Working humidity | 5-100%RH@40ºC |
Proction class | IP67 |
Sensor Seal | O-ring, FKM |
Approvals | Ex-proof, CE certificate |
Electrical connection |
Aluminum-alloy termimal,2 cable entry M20*1.5(F), red body, white cover |
Flange specifications |
HG/T 20592-2009, DN50PN10-PN40 raised face flange(max measuring range 4MPa) |
HG/T 20592-2009, DN80PN10 raised face flange(max measuring range 1MPa) | |
HG/T 20592-2009, DN100PN10 raised face flange(max measuring range 1MPa) | |
Insert tube diameter | None |
Diameter:66mm, length:50mm | |
Diameter:66mm, length:100mm | |
Diameter:66mm, length:150mm |
Measuring range and limit | ||||||
Nominal value | Smallest calibratable span |
Lower range limit (LRL) |
Upper range limit (URL) |
Static pressure limit* |
High pressure side overload limit* |
Low pressure side overload limit* |
40kPa | 4kPa | -40kPa | 40kPa | 10MPa | 10MPa | 10MPa |
250kPa | 25kPa | -250kPa | 250kPa | 10MPa | 10MPa | 10MPa |
1MPa | 10kPa | -500kPa | 1MPa | 10MPa | 10MPa | 10MPa |
Adjust requirements: lower range value (LRV) and upper range value (URV) can be adjusted within the scope of the upper and lower range limit, when | URV | ≥ | LRV | , needs | URV | ≥ smallest calibratable span; when | URV | ≤ | LRV |, needs | LRV | ≥ smallest calibratable span | ||||||
*Limit value of overpressure: depends on the pressure value of the parts with lowest pressure capacity |